University of Maryland School of Medicine logo
Emergency Medicine
All Departments
UMSOM Assistant

UMEM Educational Pearls

  • Home
  • Departments
  • Emergency Medicine
  • CME
  • UMEM Educational Pearls
  • CME
  • Courses and Conferences
  • Free Open Access Medical Education
  • UMEM Educational Pearls

Search


Subscribe to daily UMEM Pearls (FREE!) via:

Mailing List

Title: Mind the Gap

Category: Critical Care

Posted: 11/17/2026 by Jon Hurst, MD (Updated: 11/17/2026)

The anion gap (AG) represents the difference between measured cations and measured anions in the serum, reflecting the concentration of unmeasured anions.

A normal anion gap is typically 10–12 mmol/L, although reference ranges may vary.

AG = Sodium - (Chloride + Bicarb)

An elevated anion gap generally suggests an underlying metabolic acidosis due to the accumulation of unmeasured anions.

There are several situations that can affect the interpretation and calculation of the anion gap:

1. Correct for albumin.

  • A patient's expected normal anion gap can be approximated as:
    Normal AG = serum albumin × 3 (albumin in g/dL).

2. Use the measured sodium, not corrected sodium.

  • When calculating the anion gap, use the measured sodium concentration rather than the corrected sodium concentration.

3. Common causes of a low anion gap (AG less than 3 mmol/L):

  • Laboratory error (most common)
  • Hypoalbuminemia
  • Electrolyte derangements: hyperkalemia, hypercalcemia, and hypermagnesemia
  • Monoclonal gammopathies (e.g., multiple myeloma)
  • Bromide-containing medications:
    • Pyridostigmine
    • Ipratropium/tiotropium
    • Dextromethorphan
    • Rocuronium
  • Lithium toxicity
  • Salicylate poisoning (with certain laboratory assays)
  • Iodide exposure

Additional Information

1. Anion gap adjustment for albumin

  • Albumin is the major unmeasured anion in serum and contributes significantly to the anion gap. Therefore, when serum albumin is low, the patient's expected anion gap is also lower.
  • There are two commonly used approaches to account for albumin:
    • Corrected AG = Measured AG + 2.5 × (4.0 - Measured Albumin)
    • Patient's expected normal AG = Measured Albumin × 3
  • Example: If a patient's measured albumin is 2 g/dL, their expected normal anion gap would be approximately 6 mmol/L (rather than 12 mmol/L).

2. Anion gap in pseudohyponatremia and hyperglycemia

  • Pseudohyponatremia occurs when the measured sodium concentration is falsely low due to laboratory measurement interference, typically in the setting of severe hyperlipidemia or hyperproteinemia.
  • Hyperglycemia causes a low sodium concentration due to osmotic shifts (water is drawn out of cells into the extracellular space due to the hypertonicity of hyperglycemia). This results in translocational (or dilutional) hyponatremia. 
  • Although both conditions can result in a low measured sodium concentration, their underlying mechanisms are different. Pseudohyponatremia is a laboratory artifact, whereas hyperglycemia causes a true decrease in serum sodium concentration due to water redistribution.
  • In both pseudohyponatremia and dilutional hyponatremia, when calculating the anion gap, use the measured sodium concentration rather than the corrected sodium concentration.

3. Common causes of a low anion gap (list is not exhaustive)

  • Laboratory error: The most common cause of a low anion gap. Consider repeating the measurement if the result is unexpected.
  • Hypoalbuminemia: Decreased albumin results in fewer unmeasured anions, lowering the anion gap.
  • Severe electrolyte derangements: Hyperkalemia, hypercalcemia, and hypermagnesemia can increase unmeasured cations, thereby lowering the anion gap. 
  • Multiple myeloma: Positively charged monoclonal immunoglobulins (paraproteins) can act as unmeasured cations, lowering the anion gap.
  • Pseudohyperchloremia: Certain substances can interfere with chloride measurement, resulting in a falsely elevated chloride concentration and a falsely low anion gap. Examples include:
    • Bromide exposure
    • Iodide exposure
    • Salicylate toxicity (with certain laboratory assays)
  • Lithium toxicity: Lithium is an unmeasured cation thus lowering the anion gap.

References

Beck, Laurence H. “Should the Actual or the Corrected Serum Sodium Be Used to Calculate the Anion Gap in Diabetic Ketoacidosis?” Cleveland Clinic Journal of Medicine, vol. 68, no. 8, Aug. 2001, pp. 673–674. https://doi.org/10.3949/ccjm.68.8.673.

Farkas, Josh. “Diagnosis of Metabolic Acid-Base Disorders & AGMA (Including Lactic Acidosis).” EMCrit Project, 29 June 2024, https://emcrit.org/ibcc/agma/.

Haber, Lawrence A., et al. “Evaluating a Low Anion Gap: A Practical Approach.” Cleveland Clinic Journal of Medicine, vol. 90, no. 10, 2 Oct. 2023, pp. 619–623. https://doi.org/10.3949/ccjm.90a.23035.

Nickson, Chris. “Anion Gap.” Life in the Fast Lane (LITFL), 1 Jan. 2019, https://litfl.com/anion-gap/.

Wiederkehr, Michael R., et al. “Pseudohyperchloremia and Negative Anion Gap—Think Salicylate!” The American Journal of Medicine, vol. 134, no. 9, Sept. 2021, pp. 1170–1174. https://doi.org/10.1016/j.amjmed.2021.03.017.


University of Maryland School of Medicine logo
  • Departments
  • Programs
  • Research Centers
  • Institutes
  • Graduate Education
  • CIBR Cores
  • Offices of the Dean
    • University of Maryland, Baltimore
    • University of Maryland Medical Center
    • Medical Alumni Association of the University of Maryland
    • Health Sciences and Human Services Library
University of Maryland School of Medicine
655 W. Baltimore Street
Baltimore, MD 21201
Contact Us

© University of Maryland School of Medicine

    • Webmaster
    • Web Accessibility
    • Site Index
    • UMB Hotline
    • Employment
    • Map