Title: Setting PEEP in the Intubated COPD Patient

Category: Critical Care

Posted: 2/6/2024 by Mike Winters, MBA, MD

PEEP in the Ventilated COPD Patient?

  • Patients with acute respiratory failure secondary to COPD often have dynamic hyperinflation and intrinsic PEEP (PEEPi).
  • Both dynamic hyperinflation and PEEPi adversely effect pulmonary mechanics, markedly increase the work of breathing, impair respiratory muscle function, and can result in hemodynamic compromise.
  • It has traditionally been felt that the application of external PEEP in the intubated COPD patient may worsen hyperinflation.
  • Importantly, external PEEP has been shown to improve ventilator synchrony and decrease the work of breathing.
  • PEEPi is measured using an end-expiratory hold maneuver in a passive, relaxed patient.
  • External PEEP can then be set to approximately 70% of PEEPi, followed by frequent monitoring of plateau pressures in a volume-cycled ventilation mode.

References

Jubran A. Setting positive end-expiratory pressure in the severely obstructive patient. Curr Opin Crit Care. 2024; 30:89-96.


University of Maryland School of Medicine logo
  • Departments
  • Programs
  • Research Centers
  • Institutes
  • Graduate Education
  • CIBR Cores
  • Offices of the Dean
    • University of Maryland, Baltimore
    • University of Maryland Medical Center
    • Medical Alumni Association of the University of Maryland
    • Health Sciences and Human Services Library
University of Maryland School of Medicine
655 W. Baltimore Street
Baltimore, MD 21201
Contact Us

© University of Maryland School of Medicine

    • Webmaster
    • Web Accessibility
    • Site Index
    • UMB Hotline
    • Employment
    • Map