Title: LVADs and RV Failure

Category: Critical Care

Posted: 7/12/2016 by Mike Winters, MBA, MD

LVADs and RV Failure

  • Acute RV failure can be seen in up to 10% of patients after LVAD implantation.
  • The treatment of RV failure in the LVAD patient consists of the following:
    • Fluids: avoid aggressive fluid administration, as this can displace the septum and impair LVAD function
    • Inotropes: consider early initiation of dobutamine, milrinone, or epinephrine to augment RV function
    • Vasopressors: target a MAP higher than 60 to 70 mmHg to maintain RV perfusion pressure
  • If intubated, avoid hypoxia, hypercarbia, high PEEP, and high ventilator pressures.  These can increase pulmonary vascular resistance and further worsen RV function.

References

Sen A, et al. Mechanical circulatory assist devices: a primer for critical care and emergency physicians. Crit Care 2016; 20:153.


University of Maryland School of Medicine logo
  • Departments
  • Programs
  • Research Centers
  • Institutes
  • Graduate Education
  • CIBR Cores
  • Offices of the Dean
    • University of Maryland, Baltimore
    • University of Maryland Medical Center
    • Medical Alumni Association of the University of Maryland
    • Health Sciences and Human Services Library
University of Maryland School of Medicine
655 W. Baltimore Street
Baltimore, MD 21201
Contact Us

© University of Maryland School of Medicine

    • Webmaster
    • Web Accessibility
    • Site Index
    • UMB Hotline
    • Employment
    • Map