The PROTRACH study recently compared preoxygenation with standard bag valve mask (BVM) at 15 lpm to preoxygenation + apneic oxygenation with high flow nasal cannula 60 lpm/100% FiO2 in patients undergoing rapid sequence intubation.
- There was no significant difference in the primary outcome of median lowest SpO2 during intubation.
- There were more intubation complications in the BVM group compared to the HFNC group:
- Severe complications: SpO2 <80%, severe hypotension (SBP < 80mmHg or vasopressor initiation/increase by 30%), and cardiac arrest (6% HFNC vs 16% BVM, RR 0.38, 95% CI 0.15-0.95, p=0.03).
- Moderate complications: aspiration, cardiac arrhythmia, agitation, and esophageal intubation (0% HFNC vs 7% BVM, p= 0.01).
- There was no difference in ventilator days, ICU length of stay, or mortality.
References
Guitton C, Ehrmann S, Volteau C, et al. Nasal high-flow preoxygenation for endotracheal intubation in the critically ill patient: a randomized clinical trial. Intensive Care Med. 2019. doi: 10.1007/s00134-019-05529-w. [Epub ahead of print]